Previous Articles     Next Articles

Determination of benzo[a]pyrene in Tegillarca granosa by solid phase extraction\|high performance liquid chromatography with fluorescent detector

  

  1. (1 Zhejiang Mariculture Research Institute, Wenzhou 325005, China; 2 Zhejiang Key Laboratory of Exploitation and Preservation of Coastal Bio\|resource, Wenzhou 325005, China; 3 School of Laboratory, Medicine and Life Science, Wenzhou Medical University, Wenzhou 325035, China)
  • Online:2015-05-25 Published:2015-05-19
  • Supported by:
    Determination of benzo[a]pyrene in Tegillarca granosa by solid phase extraction\|high performance liquid chromatography with fluorescent detector

Abstract: A method of solid phase extraction\|high performance liquid chromatography with fluorescent detector (HPLC\|FLD) was developed for the determination of benzo[a]pyrene(B[a]P) in Tegillarca granosa. The analytical procedure included extraction using n\|hexane by ultra\|sonic oscillation, purification using a B[a]P special SPE column and detection by a fluorescent detector. The method exhibited a good linearity over the range of 001-1 μg·mL-1 for benzopyrene with r=0999 2. The average recovery rate was 8147%~8471% and the relative standard deviation was 48%~88% (n=6). Under optimized conditions, the detection limit of this method was 03 μg·kg-1, and the detection limits of the detector was 10 ng·mL-1. In conclusion, the proposed method exhibited advantages of easy to operate, fast to perform, and high sensitivity and accuracy.

Key words: benzopyrene, Tegillarca granosa, high liquid chromatography\, fluorescent detection, solid phase extraction